RC-100 Heat Pump Thermostat
|
|
RC-100 Single stage Thermostat for heat pumps.1 stage heat, 1 stage cool. Can be set to heat only or cool only. Automatic anticipator. Use for Heat Pumps. Thermostat can "power steal" for retrofitting heat/cool systems with only 4 wires.
Single stage heat pumps with auxiliary heating
2 stage heat, 1 stage cool
Energy Efficient Control of auxiliary heat to save energy (EEC can be turned off if desired)
Automatic anticipator
Use for: water source heat pumps, ground source heat pumps, or air to air heat pumps with electric, hot water, or other source of auxiliary heat
Terminals:
R - transformer hot
G - fan
O - energized on cooling (for reversing valve)
B - energized on heating (for reversing valve)
C - transformer common
Y - compressor (heating and cooling)
W2 - auxiliary heating (stage 2 heat)
X2 - fault indicator LED
|
RC-100 Heat Pump User's Manual:
Download The User's Manual
|
Wiring Requirements:
Wire thermosat to furnace/air handler as any programmable thermostat, PLUS install a four conductor #22 awg jacketed cable from thermostat to OMNI Controller for Serial Communications
|
|